GE Ohmeda Care Plus 4000 Infant Incubator - Refurbished

  • Dovetail Rail system
  • Standard Humidifier for variable control of humidity
  • Care Plus 3000: Three-position tilt for easy, precise adjustment to 0º,3º, and 6º at either end of the bed
  • Care Plus 4000: Continuous Tilt allows smooth, unlimited adjustment from 0º to 12º

Integrates microprocessor-based controls with a modular design for efficient patient care. The GE Ohmeda Care Plus 4000 is an advanced incubator that provides superior thermoregulation with an integrated microprocessor-based controller. Optional active double-wall construction creates a precise and consistent environment for the neonate.

GE Ohmeda Care Plus 4000 Specifications

Dimensions

Incubator with Elevating Base:

  • Height: Overall height 54 to 62 inches (136.2 to 157.5 cm)
  • Elevating base adjustable from 35 to 43 inches (88.9 to 109.2 cm) mattress to floor
  • Depth: 71.1 cm/28 in
  • Width: 83.8 cm/33 in
  • Weight: 89 kg/195 lb

Incubator with Elevating Base:

  • Height: Overall height 54 to 62 inches (136.2 to 157.5 cm)
  • Elevating base adjustable from 35 to 43 inches (88.9 to 109.2 cm) mattress to floor
  • Depth: 71.1 cm/28 in
  • Width: 83.8 cm/33 in
  • Weight: 89 kg/195 lb

Drawer Packages for Elevating Base or Stationary Pedestal:

  • Overall: 28 x 29 x 46 cm/11 x 11.5 x 18.25 in
  • Single deep drawer: 25 x 23 x 42 cm/10 x 9 x 16.5 in
  • Dual drawer: 11 x 23 x 42 cm/4.5 x 9 x 16.5 in

Incubator with Cabinet:

  • Height: 141 cm/55 in
  • Depth: 64.6 cm/25.5 in
  • Width: 88.9 cm/35 in
  • Weight: 84 kg/185 lb

Incubator Characteristics:

  • Casters: 5 inch diameter, 2 locking, 2 non-locking
  • Mattress: 34.8 x 65 cm/13.7 x 25.6 in
  • Mattress to Hood: 16 in/41 cm
  • Door Height: 11 in/28 cm
  • Tilt: 0°, 3° and 6° (CP 3000)
  • Positions: Continuous from 0° to 12° (CP 4000)
  • Port holes: 6
  • Tubing ports: 6

Electrical Power Requirements

  • 120 Vac 60Hz
  • Models: 115 V ±10% 5.7 amps
  • Conforms to IEC 601.1, UL 544 and CSA 22.2 No. 125 requirements
  • Nominal power consumption: 450 watts at maximum heater output
  • Line voltage compensation: Input voltage is monitored and the heat output is adjusted to compensate for line voltage variations
  • Leakage currents: Less than 100 micro amps on 120V units
  • Leakage at patient probe: Less than 50 micro amps on 120V unit

Operation Enviroment

  • Operating temperature range: 20° to 30°C/68° to 86°F
  • Storage temperature range: -25° to 60°C/13° to 140°F
  • Operating humidity range: 0 to 90%

System Control Characteristics

  • Microprocessor based control system: Self-test functions are performed at power-up and during normal operation
  • Patient Control (Servo) Mode: 35° to 37°C/95° to 98.6°F
  • Air Control (Manual) Mode: 20° to 37°C/73.4° to 98.6°F
  • Up to 39°C/102.2°F with control panel override switch
  • Air Velocity: Average <10 cm/sec with inner wall
  • Temperature variability: Less than ±0.3°C
  • Resolution: ±0.1°C or 0°F
  • Probe interchangeability: ±0.1°C/0.2°F
  • Average oxygen input concentration range:
    • 5 L/min 25 to 45%
    • 10 L/min 35 to 65%
    • 15 L/min 45 to 70%
  • Humidification: Standard – 10 to 75% dependant on nursery environment and incubator temperature setting
  • Servo – 40

 